My Cart:

0 item(s) - $0.00
You have no items in your shopping cart.

0

Welcome to the Scitek online store!
We ship globally

Toll Free: 1800 023 467

More Views

QMG 220 M3. PrismaPlus. 1-300 amu. gas tight ion source

Quick Overview

QMG 220 M3. PrismaPlus. 1-300 amu. gas tight ion source
- PTM06321111

Availability: Call For Availability

QMG 220 M3. PrismaPlus. 1-300 amu. gas tight ion source is available for purchase in increments of 1

Details

  • Cost-effective residual gas analysis and vacuum process monitoring in the high and ultra high vacuum ranges
  • For use in combination with gas inlet systems; low gas consumption. high signal-to-noise ratio
  • High measuring speed. stability and resolution
  • Interchangeability of analyzers and electronics
  • Mass range 1-300 amu for analytical measurement tasks. even in the higher measurement range
  • Mass range 1-300 amu for residual gas analysis and analytical measurement tasks. even in the higher measurement range
  • Optimum availability thanks to two filaments
  • Optimum availability thanks to two filaments
  • PrismaPlus compact mass spectrometer
  • Quadera software for Windows XP Professional and Vista Ultimate
  • Simple definition and launching of measurement recipes
  • Determination of gas concentrations by means of integrated matrix calculation
  • Ethernet networking
  • Analog and digital inputs and outputs
  • Connectable to a Pfeiffer Vacuum total pressure gauge
Bakeout temperature: analyzer200 *C
Connection0*
Connection for gaugeConnection for one ActiveLine- and DigiLine- gauge
Contribution to neighboring mass: 40 to 41 50 ppm
Description accessoriesAccessories for optimum adaptation of the mass spectrometer to the measurement task at hand.
Detection limit min.: C-SEM 4.10-14 hPa
Detection limit min.: Faraday2.10-11 hPa
DetectorC-SEM/Faraday
EMCEN 61326-1
FilamentTungsten
Flange (in)DN 40 CF-F
Input: Analog5 x +/- 10 V / 14 Bit
Input: Digital4 + EXT_PROTECTION. 24 V
InterfacesEthernet
Ion sourceGas tight. 2 filaments
Mass range1-300 amu
Measuring channels128 pieces
Mounting orientationAny
Operating pressure max.: C-SEM1.10-5 hPa
Operating pressure max.: Faraday1.10-4 hPa
Operating temperature: analyzer150 *C
Operating temperature: electronics0-40 *C
Output: Analog4 x 0-10 V / 12 Bit
Output: Digital16 x Sink. optical insulated. 24 V
Peak ratio reproducibility+/- 0.5 %
Resolution. adjustable at 10 % peak height0.5 - 2.5 amu
Rod system: Diameter6 mm
Rod system: Length100 mm
SafetyEN 61010-1 / IEC 1010
Scan speed: MID2 ms - 60 s/amu
Scan speed: scan analog20 ms - 60

Product Tags