HPA 220. 8 hPa. HPI 040 P

Quick Overview

HPA 220. for process pressure up to 8 hPa. HPI 040 P
- PTM51120

Availability: Call For Availability

HPA 220. 8 hPa. HPI 040 P is available for purchase in increments of 1

Details

  • Compact dimensions for flexible integration
  • Easy and flexible system integration through a variety of digital and analog inputs and outputs
  • Multiplex operation allows data evaluation of several mass spectrometer systems with a single PC
  • Provides great flexibility thanks to 5 manually or electropneumatically operated gas inlet options for analyzing. monitoring and controlling processes up to a pressure of 50 hPa
  • HPA 220. High Pressure Analyzer. mass range 1-100 amu. 115-230 V. 50/60 Hz. for process gas and residual gas analysis at pressure range 8 hPa p 1 - 10-7 hPa consisting of:
  • PrismaPlus with quadrupole electronics QME 220. quadrupole analyzer QMA 200 M with open ion source and two tungsten filaments
  • Valve interface HPI 040 P. electro pneumatically operated. DN 40 CF-F. with one gate valve with nominal diameter 40 mm for leak test and residual gas analysis at high vacuum. two bypass valves with exchangeable orifices (0.1 and 0.3 mm) to match two different pressure ranges. A third orifice. 0.03 mm. is enclosed
  • Valve control unit VCU 220 and HPA-valve-Add-In for Quadera
  • System control unit BRU 220 with power supply TPS 311 and remote connector for external access
  • Turbo-molecular-pump station with HiPace 80 and roughing pump MVP 020-3 DC
  • Total pressure gauge PKR 251
  • Set of cables. 3 meter
  • Quadera-Software for Windows 7. XP Professional (32bit) for parameterisation of PrismaPlus system and for storage and showing measurement data
AnalyzerQMA 220
Backing pumpMVP 020-3
Cable length3 m
Compressed air5-7 bar
Description accessoriesAccessories for optimum adaptation of the mass spectrometer to the measurement task at hand.
Detection limit min.: C-SEM1.10-14 hPa
Detection limit min.: Faraday5.10-12 hPa
DetectorC-SEM/Faraday
Flange (in)DN 40 CF-F
Mass range1-100 amu
Process pressure to8 hPa
Quadrupole controllerQME 220 M
Rod system: Diameter6 mm
Rod system: Length100 mm
Rod system: MaterialStainless steel
Sensitivity for Ar: C-SEM200 A/hPa
Sensitivity for Ar: Faraday5.10-4 A/hPa
SoftwareQuaderaTM
Supply115-230 V
System controlBRU 200
TurbopumpHiPace 80 with TC 110 RS
Valve control unitVCU 220
Valve interface with orifices O 0.1 mm und 0.3 mmHPI 040. electropneumatically actuated
Weight: Analyzer incl. Turbo15 kg